| At line 2 added 5 lines. | 
| + More Information on intranet page (drawing): [LdmWiki:MA09] | 
| + | 
| + [ma09a.jpg] | 
| + [ma09b.jpg] | 
| + | 
| Lines 14-16 were replaced by lines 19-21 | 
| - |TASP         |6 Tesla       |with goniometer, goniometer motors removed | 
| - |TASP         |9 Tesla       |without goniometer unit | 
| - |Rita-II      |4 Tesla       |with goniometer, goniometer motors removed | 
| + |TASP         |6 Tesla       |with goniometer, goniometer motors removed, distance to Be filter: > 20 cm | 
| + |TASP         |9 Tesla       |without goniometer unit, monochromator 2theta > 75, distance to Be filter[1]: > 22 cm\\7.9 Tesla: 2theta > 55 ? | 
| + |Rita-II      |4 Tesla\\9 Tesla|with goniometer, goniometer motors removed\\without goniometer | 
| Lines 18-20 were replaced by lines 23-25 | 
| - |HRPT         |??            |force measurements to be redone | 
| - |FOCUS        |9 Tesla       |magnetic rail and motor of radial collimator removed//distance magnet center to mono center 2 m, 2theta < 132 deg or magnet surface to guide surface > 0.9 m | 
| - |TriCS        |4 Tesla       | | 
| + |HRPT         |4 Tesla       |without RC shielding [2] | 
| + |FOCUS        |9 Tesla       |magnetic rail and motor of radial collimator removed\\distance magnet center to mono center 2 m, 2theta < 132 deg or magnet surface to guide surface > 0.9 m | 
| + |TriCS        |2 Tesla       |due to problems with omega-encoder (from the forces 4 T is possible) | 
| At line 22 added 4 lines. | 
| + [1|#1] on TASP: [MA09/taspFilterMA09.png] | 
| + | 
| + [2|#2] on HRPT: [MA09/RCshielding.jpg][MA09/RCmotor.jpg]\\ | 
| + The RC shielding (left picture) has to be removed. One of the pieces making trouble is probably the RC motor (right picture). | 
| At line 23 added 2 lines. | 
| + On all other Instruments, MA09 can not yet be used. | 
| + | 
| Lines 26-28 were replaced by lines 37-44 | 
| - * The magnet seems not to work reliably with the lambda stage | 
| -   (2 quenches during an expt. in November 2006). The reason is not | 
| -   yet clear. A user claimed that the switch heater power is too low | 
| + * The magnet has a cold leak, occuring only occasionaly at low temperatures. | 
| +   As a workaround the main vacuum has to be pumped constantly. (Oct 2006) | 
| + | 
| + ! Solved issues | 
| + | 
| + * The magnet seemed not to work reliably with the lambda stage | 
| +   (2 quenches during an expt. on TASP in November 2006). The reason is | 
| +   not yet clear. A user claimed that the switch heater power is too low | 
| At line 35 added 2 lines. | 
| +   We now believe that during the quench, the magnet was too close to the | 
| +   magnetic beam dump of TASP. | 
| Removed lines 37-41 | 
| - * The magnet has a cold leak, occuring only occasionaly at low temperatures. | 
| -   As a workaround the main vacuum has to be pumped constantly. (Oct 2006) | 
| - | 
| - ! Solved issues | 
| - | 
| At line 44 added 4 lines. | 
| + | 
| + | 
| + [TASP adapter| taspMa9_1.jpg] [TASP adapter |taspMa9_2.jpg] | 
| + |