Diff: DIL2

Search SINQ Wiki:
SINQ LIN

SINQ Wiki
- Main Page
- Search SINQ Wiki
- Sample Environment
- Probenumg. Intern
- Troubleshooting SICS

This Page
- Page Info
- Printer Friendly

Referenced by
RemoveMixtureDIL
DilSampleMounting
DilutionCryostats
EarlierProgress

Wiki Info
- Unused pages
- Undefined pages
- RecentChanges
- Page Index
- System Info
- JSPWiki Docu
- SandBox
- OneMinuteWiki
- Create a New Page




JSPWiki v2.0.52


Difference between version 38 and version 4:
At line 1 added 1 line.
+ [{Image src='DIL2/dil2.jpg' align='right'}]
Line 6 was replaced by line 7
- It is equipped with a weak link, allowing access to the
+ It is equipped with a [weak link|Dil2WeakLink], allowing access to the
At line 8 added 4 lines.
+ [Sample Mounting|DilSampleMounting]
+
+ [DIL1/dilGeometry.gif]
+
Lines 10-21 were replaced by lines 15-21
- * The weak link is too weak. For the first experiments we
- will use a simple copper sample holder, and use the sensor
- on the mixing chamber.
-
- !DIL2 Sample mounting
- |used in||MA15||MA11||MA02||MA09
- |sample space diameter [[mm]|17.3|17.3|23.6|45
- |max. sample diameter [[mm]|12|12|18|35
- |distance from thread to beam center [[mm]\\adjustable by about +- 10 mm|40|51|97|194
- |allowed size below beam center [[mm]|64|30|60|24
- On the mixing chamber, there is a bolt with an M5 thread
- (on the sample container a 7 mm deep hole with an M5 thread is needed).
+ * The weak link was too weak, and there was no spacer on it.
+ We have shortened the weak section and put a spacer above
+ it.
+
+ * The gauges G1 and G2 do not work reliably. As a workaround,
+ the (earlier unused) G3 gauge has now a connection to the
+ beam dump.
Lines 31-32 were replaced by line 31
- *Sensor Calibration
-
+ !Sensor Calibration
Lines 34-51 were replaced by lines 33-50
- is generic. For more precise values use the following table.
- ||Mix.Ch.||Display||Sample
- |0.043|0.040|0.036
- |0.063|0.060|0.055
- |0.084|0.080|0.075
- |0.104|0.100|0.094
- |0.155|0.150|0.143
- |0.205|0.200|0.191
- |0.306|0.300|0.289
- |0.407|0.400|0.387
- |0.609|0.600|0.581
- |0.811|0.800|0.777
- |1.013|1.000|0.972
- |1.521|1.500|1.461
- |2.029|2.000|1.951
- |3.050|3.000|2.938
- |4.075|4.000|3.929
- |5.105|5.000|4.925
+ is generic. For more precise values use the table below.
+ ||Display||Mix.Ch.
+ |0.040|0.042
+ |0.060|0.063
+ |0.080|0.084
+ |0.100|0.105
+ |0.150|0.156
+ |0.200|0.206
+ |0.300|0.306
+ |0.400|0.404
+ |0.600|0.600
+ |0.804|0.800
+ |1.01 |1.00
+ |1.52 |1.50
+ |2.03 |2.00
+ |3.04 |3.00
+ |4.02 |4.00
+ |5.00 |5.00

Back to DIL2, or to the Page History.