2 Electrical Wiring
2.1 Cryostat Wiring
SYMMETRIC ENERGISATION (8/9 TESLA)
Coaxial current lead terminal on tall cryostat services neck (this neck also features the VTI needle valve):
- Inner terminal post I+ (start of entire magnet, internal red wire)
- Outer terminal post I- (end of entire magnet, internal black wire)
ASYMMETRIC ENERGISATION (4 TESLA)
Co-axial current lead terminal on short cryostat services neck (this neck also features the syphon entry port):
- Inner terminal post I+ (start of selected coils, internal blue wire)
- Outer terminal post I+ (end of selected coils, internal brown wire)
Ten pin connector on services neck with syphon entry:
- Connections to persistent mode switch heaters
Ten pin connector on services neck with lambda point refrigerator needle valve and pumping line:
- Connections to carbon resistors for monitoring lambda point refrigerator.
Ten pin connector on services neck with VTI needle valve:
- Connections to helium level probe.
VTI WIRING.
Ten pin connectors on VTI top plate:
- VTI heat exchanger thermometry and non-inductive heater.
Ten pin connector on cryostat top plate:
- Heater and carbon resistor for clearing VTI needle valve blockages.
Five pin connector on services neck with motor drive:
- Auto-needle valve control for the VTI. (not mounted).
Original Risų Cabling:
2.2 Magnet Winding
Attachments:
SwitchHeaterPlug.gif
InternalWiring.gif
OriginalRisoeCables.gif
VTIPlug.gif
NeedleValvePlug.gif
AllenBradleyPlug.gif
This particular version was published on 16-Feb-2005 13:41:39 UTC by MarkusZolliker.
|