Difference between
version 75
and
version 73:
At line 1 added 4 lines. |
+ |
+ The best-practices and useful tips for running a pressure experiment are summarized here:\\ |
+ [https://www.psi.ch/en/lin-sept/high-pressure-experiments|https://www.psi.ch/en/lin-sept/high-pressure-experiments] |
+ |
Lines 11-12 were replaced by lines 15-16 |
- |[P10]|JW|clamp cell for single crystal inelastic or elastic ns|10-12 kbar at RT, 8-10 kbar at 1.5K|ILL2, ILL5|FOCUS, TASP, RITA-II, EIGER, ZEBRA|d=7, c=25 |
- |[P17]|JW|clamp cell for single crystal inelastic or elastic ns|15-17 kbar at RT, 13-15 kbar at 1.5K|ILL5|FOCUS, TASP, RITA-II, EIGER, ZEBRA|d=7, c=25 |
+ |[P10]|GS|clamp cell for single crystal inelastic or elastic ns|10-12 kbar at RT, 8-10 kbar at 1.5K|ILL2, ILL5|FOCUS, TASP, RITA-II, EIGER, ZEBRA|d=7, c=25 |
+ |[P17]|GS|clamp cell for single crystal inelastic or elastic ns|15-17 kbar at RT, 13-15 kbar at 1.5K|ILL5|FOCUS, TASP, RITA-II, EIGER, ZEBRA|d=7, c=25 |
Line 14 was replaced by line 18 |
- |[P10_NMS]|JW|non-magnetic clamp cell for single crystal inelastic or elastic ns|8-10 kbar at RT, 7-8 kbar at 1.5K|ILL2, ILL5, MA09, MA07|FOCUS, TASP, RITA-II, EIGER, ZEBRA, SANS-I, SANS-II|d=8, c=20 |
+ |[P10_NMS]|GS|non-magnetic clamp cell for single crystal inelastic or elastic ns|8-10 kbar at RT, 7-8 kbar at 1.5K|ILL2, ILL5, MA09, MA07|FOCUS, TASP, RITA-II, EIGER, ZEBRA, SANS-I, SANS-II|d=8, c=20 |
Line 16 was replaced by line 20 |
- |[PE]|JW|Paris-Edinburgh press (opposed anvils)|100 kbar at RT, 50kbar at 20K|The press has a RT mode, or a dedicated CCR for low T mode|HRPT, DMC for powders, RITA-II for single crystal|d=5, c=1.5 |
+ |[PE]|GS|Paris-Edinburgh press (opposed anvils)|100 kbar at RT, 50kbar at 20K|The press has a RT mode, or a dedicated CCR for low T mode|HRPT, DMC for powders, RITA-II for single crystal|d=5, c=1.5 |
Back to PressureDevices,
or to the Page History.
|