Diff: OmegaMotorChangeOnRita2

Search SINQ Wiki:
SINQ LIN

SINQ Wiki
- Main Page
- Search SINQ Wiki
- Sample Environment
- Probenumg. Intern
- Troubleshooting SICS

This Page
- Page Info
- Printer Friendly

Referenced by
MA15

Wiki Info
- Unused pages
- Undefined pages
- RecentChanges
- Page Index
- System Info
- JSPWiki Docu
- SandBox
- OneMinuteWiki
- Create a New Page




JSPWiki v2.0.52


Difference between version 12 and version 4:
Line 1 was replaced by line 1
- !Procedure to Change from/to the Omega Motor on the Sample Stick
+ !!Procedure to Change the Option for the Sample Stick Rotation
Lines 3-6 were replaced by lines 3-6
- Make sure that the serial line (RS232) to the motor controller
- is connected and that the motor controller is switched on.
- The cables have to be connected, before the motor controller is switched on,
- otherwise you will not be able to drive the motor.
+ There are 7 options now:
+ ;{{set stickmotor 0}}:''Normal mode: motor __om__ is sample table''
+ ;{{set stickmotor 1}}:''MA15 mode: motor __om__ is sample stick, motor __sro__ is sample table''
+ ;{{set ma15motor 2}}:''MA02 mode: motor __om__ is sample table, motor __stick__ is sample stick''
Line 8 was replaced by lines 8-9
- In /home/rita2/rita2_sics/rita2.tcl change the following line
+ !Change to Omega on Sample Stick (for MA15)
+ * In {{/home/rita2/rita2_sics/rita2.tcl}} change the following line
Line 10 was replaced by line 11
- set ma15motor 1 (1 for motor on sample stick, 0 for normal omega table)
+ set stickmotor 15
Line 12 was replaced by line 13
- and then restart sics with the command
+ * Stop the SICS server at the unix prompt:
Line 14 was replaced by line 15
- monit restart sicsserver
+ monit stop sicsserver
Line 16 was replaced by lines 17-26
- on the unix prompt.
+ * Switch off the motor controller (if not already off)
+ * Make sure that the cables to the rotation unit are connected, and
+ that the serial line (RS232) to the motor controller is connected.
+ * Switch on the motor controller.
+ * Start sics with the command
+ {{{
+ monit start sicsserver
+ }}}
+
+ ''Outdated information:''
Line 21 was replaced by line 31
- el734_test -help
+ el734_test -help
Line 23 was replaced by line 33
- for documentation. A parameter file can be found under /home/users/tascom/PSI/mot_4_01.par
+ for documentation. A parameter file can be found under /home/users/tascom/PSI/mot_4_01.par (no longer there!)

Back to OmegaMotorChangeOnRita2, or to the Page History.