This is version 12.
It is not the current version, and thus it cannot be edited.
[Back to current version]
[Restore this version]
MA15 Restrictions on TASP
The operation on TASP is allowed up to a field of 15 Tesla for A2 angles between -45 and -100.
The distance to the monochromator must be 630 mm or more, and the distance to the beryllium filter
250 mm. See pictures how to measure:
Force measurements 20. April 2012
Summary: Distance as above, at 8.6 Tesla, a2=-48, a4=105: vertical force 440 N, horizontal force 210 N.
Report by Martin Mansson
Force test 27. July 2015
Conditions:
- Ei =11meV == a2 = -47.97deg
- a4 = 105deg
- Be-filter installed
- dist. Magnet-filter: 260mm
- dist. mono-table: 630mm
Both vertical and horizontal forces stay below the specified maximum allowance.
In this configuration the magnet can be used up to 15T.
Attachments:
TASP_M15_forcetest.pdf
foto3.jpg
vertiforce.png
MA15filterDistanceTASP.jpg
foto2.jpg
MA15sampleDistanceTASP.jpg
foto1.jpg
horiforce.png