Diff: TasVariables

Search SINQ Wiki:
SINQ LIN

SINQ Wiki
- Main Page
- Search SINQ Wiki
- Sample Environment
- Probenumg. Intern
- Troubleshooting SICS

This Page
- Page Info
- Printer Friendly

Referenced by
NewTasSyntax

Wiki Info
- Unused pages
- Undefined pages
- RecentChanges
- Page Index
- System Info
- JSPWiki Docu
- SandBox
- OneMinuteWiki
- Create a New Page




JSPWiki v2.0.52


Difference between version 9 and version 3:
Line 2 was replaced by line 2
- ;DM,DA: Monochromator/Analyser d-spacing [Angstroem].
+ ;DM,DA: Monochromator/Analyser d-spacing [[Angstroem].
Removed lines 5-8
- ;AS,BS,CS: unit cell constants [Angstroem]
- ;AA,BB,CC: unit cell constants [degrees]
- ;AX,AY,AZ: Components of a recip. lattice vector in scattering plane of the sample. A3 is the angle between KI and (AX,AY,AZ).
- ;BX,BY,BZ: Components of a second distinct recip. lattice vector in scattering plane.
Lines 11-13 were replaced by lines 7-9
- ;ALF1,ALF2,ALF3,ALF4: Horizontal collimation before mono, before sample, before analyser, before detector [minutes FwHm]
- ;BET1,BET2,BET3,BET4: Vertical collimation before mono, before sample, before analyser, before detector [minutes FwHm]
- ;ETAM,EATS,ETAA: Monochromator/Sample/Analyser mosaic [minutes FwHm]
+ ;ALF1,ALF2,ALF3,ALF4: Horizontal collimation before mono, before sample, before analyser, before detector [[minutes FwHm]
+ ;BET1,BET2,BET3,BET4: Vertical collimation before mono, before sample, before analyser, before detector [[minutes FwHm]
+ ;ETAM,EATS,ETAA: Monochromator/Sample/Analyser mosaic [[minutes FwHm]
Lines 17-19 were replaced by lines 13-14
- Lower and upper limits and zeros for all variables given in (iv)
- below. L, U and Z are appended as a prefix to the variable names to
- indicate Lower limit, Upper limit and Zero.
+ Lower and upper limits and zeros for all motors. L, U and Z are appended
+ as a prefix to the variable names to indicate Lower limit, Upper limit and Zero.
Lines 28-29 were replaced by lines 23-24
- A5 Analyzer angle (Bragg angle in deg, TOPSI: not used)
- A6 Scattering angle at analyzer (twice A5 in deg., TOPSI: not used)
+ A5 Analyzer angle (Bragg angle in deg.)
+ A6 Scattering angle at analyzer (twice A5 in deg.)
Removed line 31
- SINQ Instruments:
Lines 60-62 were replaced by line 54
- QH -\
- QK +-- Components of Q in Reciprocal Lattice Units [R.L.U.]
- QL -/
+ QH Q in Reciprocal Lattice Units (3 components!)
Lines 70-95 were replaced by line 62
- IF1V IF1V and IF2V are currents [Amps] in the vertical-field
- IF2V coils for Flipper 1 and Flipper 2.
- IF1H Horizontal-field currents are KI*IF1H for Flipper1 and
- IF2H KF*IF2H for F2.
- HELM Angle between axis of Helmholtz pair one and KI.
- F1 -\ Status of flippers one and two; these variables take the
- F2 -/ values ON or OFF.
-
- ''Currents''
- I1 -\
- I2 \
- I3 +-- power supply current values [A]
- . /
- I11 -/
-
- ''Field''
- HX -\ Components of Helmholtz fields at sample in Oersteds.
- HY +-- HX is parallel to Q and HY is perpendicular to Q in
- HZ -/ the scattering plane.
-
-
- !Increments Variables
-
- For all motors, virtual motors, currents and field
- the identifier for the step used with a SCan command is obtained
- by prefixing the variable name with the letter D.
+ not yet specified

Back to TasVariables, or to the Page History.