Difference between version 104 and version 19:
Lines 1-7 were replaced by line 1
- ||Name||Description ||Field ||Temp. ||d ||a ||b||Thread
- |[MA15]|Oxford Instr. Cryomagnet |vert. 14.9 T |1.6...300 K |20 |14...90 |139|M6
- |[MA11]|Oxford Instr. SANS Cryomagnet|hor. 11 T |1.8...300 K |22 | | |M8
- |[MA09]|Oxford Instr. Cryomagnet |vert. 9 T |1.8...300 K\\>100 mK[1]|48 |93...137[2]|58|M20x1
- |[MA02]|Oxford Instr. Cryomagnet |hor. 1.8 T |1.8...300 K |28 | 0...56 |93|M20x1
- |[MA4] |Thor Cryomagnet |vert. 4 T |4.2...100 K  |24.5|37...71|29|M6
- |not yet named|Electromagnet (TASP only)|vert. 20 mT\\hor. 2 mT|any (in combination\\with almost any\\temperature device)| | | |
+ !Cryomagnets
At line 8 added 14 lines.
+ The sample mounting thread on all sticks is M6 (female).\\
+ Please read also the [rules concerning superconducting magnet experiments|MagnetDilutionPolicy]\\
+ and the [Introduction on cryogenic handling |http://lns00.psi.ch/sinqwiki/Wiki.jsp?page=CryogenicHandling]\\
+
+ ||Name||Description||Field||Temp.||d\\(without\\[dilution|DilSampleMounting]) ||a\\[[mm]||b\\[[mm]|| L\\[[mm]||g\\[[mm]||h\\[[mm]
+ |[MA15]|Oxford Instr. Cryomagnet |vert. 14.9 T |1.6...300 K\\>80 mK[1] |20 |14...90 | 139| __1454__ |49.5|1238(+2)
+ |[MA11]|Oxford Instr. SANS Cryomagnet|hor. 11 T |1.8...300 K\\>80 mK[1] |22 |75...100[3]|54| __1462__ |49.5 (62)|1240(+2)
+ |[MA7] |Oxford Instr. Cryomagnet |hor. 6.8 T |1.8...300 K\\>80 mK[1] |48 |35...90 | 69| __1517__ |49.5|
+ |[MA6] |Oxford Instr. Cryomagnet |vert. 6 T |1.8...300 K\\>80 mK[1] |30 |40...90 | 80| __1469__ |49.5|1078(+2)
+ |[MA02]|Oxford Instr. Cryomagnet |hor. 1.8 T |1.8...150 K[4]\\>100 mK[1] |28 | 0...56 | 93| __1405__ |55 |968(+2)
+ |[MA10]|Oxford Instr. Cryomagnet |vert. 10 T |1.8...300 K\\>80 mK[1] |48 | | 115| __1275__ |49.5|
+ |[MB11]|Oxford Instr. Cryomagnet |vert. 11T |1.8..300K\\>50mK[1] |100|50...150| 150| __1551__[2] |100 |
+ |''[MA09]''|''out of service'' |vert. 9 T |1.6...320 K\\>80 mK[1] |48 |93...137[3]|58| __1247__ |55 |
+
Line 10 was replaced by lines 18-19
- d: sample space diameter\\
+ [dimensions|HeCryostats/ORIdimensions.png]\\
+ d: sample space diameter (reduce by 2-4 mm for max. sample diameter)\\
Line 13 was replaced by lines 22-32
- M6,M8,M20x1: a hole on the stick with the specified thread
+ L: length from top flange to the center of the sample, including rotation stage (when used without, reduce by 160). Please be aware that the values given are to measured at RT, a 2-3 mm shrinking at low T is already considered.\\
+ g: diameter of upper part of sample stick space\\
+ h: length of upper (larger) part of sample stick space (+2mm when warm)\\
+ The allowed sample diameter in combination with a dilution can be found [here|DilSampleMounting]\\
+
+ [1|#1] in combination with dilution sticks\\
+ [2|#2] the rotation stage can not be removed\\
+ [3|#3] as we have adapter pieces, it is recommended to make the sample
+ holder with a distance from thread to the sample center between 37 and 50 mm\\
+ [4|#4] for a short time 300 K is possible, but not recommended due
+ to very high liquid He consumption\\
Lines 15-17 were replaced by line 34
- [1|#1] in combination with dilution stick\\
- [2|#2] as we have adapter pieces, it is recommended to make the sample
- holder with a distance from thread to the sample center between 37 and 50 mm
+ [Strayfields]
At line 21 added 6 lines.
+
+ !Electromagnets
+
+ ||Instruments||Description||Field
+ |TASP | Guide field magnet | vert. 20 mT\\hor. 2 mT
+ |SANS-I, SANS-II, AMOR|Electromagnet| hor. < 1.5 T

Back to MagnetList, or to the Page History.