Removed lines 5-9 |
- Please refer to the cryostat and magnet general assembly drawing in conjunction with the diagrams above. |
- |
- |
- ''2.1.1 Magnet Service Necks'' |
- |
Lines 12-18 were replaced by lines 7-9 |
- Coaxial current lead terminal on tall cryostat services neck |
- (this neck also features the VTI needle valve): |
- lnner terminal post l+ (start of entire magnet) |
- (red wire from magnet) |
- Outer terminal post 1- (end of entire magnet) |
- (black wire from magnet) |
- |
+ Coaxial current lead terminal on tall cryostat services neck (this neck also features the VTI needle valve): |
+ * Inner terminal post I+ (start of entire magnet, internal red wire) |
+ * Outer terminal post I- (end of entire magnet, internal black wire) |
Removed line 20 |
- ASYMMETRIC ENERGISATION (4 TESLA) Co-axial current lead terminal on short cryostat services neck (this neck also features the syphon entry port):lnner terminal post l+ (start of selected coils) |
Line 22 was replaced by line 12 |
- (blue wire from magnet) |
+ ASYMMETRIC ENERGISATION (4 TESLA) |
Lines 24-25 were replaced by lines 14-16 |
- Outer terminal post 1+ (end of selected coils) |
- (brown wire from magnet) |
+ Co-axial current lead terminal on short cryostat services neck (this neck also features the syphon entry port): |
+ * Inner terminal post I+ (start of selected coils, internal blue wire) |
+ * Outer terminal post I+ (end of selected coils, internal brown wire) |
Line 27 was replaced by lines 18-20 |
- Ten pin connector on services neck with syphon entry :Connections to persistent mode switch heaters. |
+ Ten pin connector on services neck with syphon entry: |
+ * Connections to persistent mode switch heaters |
+ [MA09WiringManual/SwitchHeaterPlug.gif] |
Line 29 was replaced by lines 22-24 |
- Ten pin connector on services neck with lambda point refrigerator needle valve and pumping line:Connections to carbon resistors for monitoring lambda point refrigerator. |
+ Ten pin connector on services neck with lambda point refrigerator needle valve and pumping line: |
+ * Connections to carbon resistors for monitoring lambda point refrigerator. |
+ [MA09WiringManual/AllenBradleyPlug.gif] |
Line 31 was replaced by lines 26-27 |
- Ten pin connector on services neck with VTI needle valve :Connections to helium level probe. |
+ Ten pin connector on services neck with VTI needle valve: |
+ * Connections to helium level probe. |
Line 36 was replaced by lines 32-38 |
- Ten pin connectors on VTI top plate :VTI heat exchanger thermometry and non-inductive heater. |
+ Ten pin connectors on VTI top plate: |
+ * VTI heat exchanger thermometry and non-inductive heater. |
+ [MA09WiringManual/VTIPlug.gif] |
+ |
+ Ten pin connector on cryostat top plate: |
+ * Heater and carbon resistor for clearing VTI needle valve blockages. |
+ [MA09WiringManual/NeedleValvePlug.gif] |
Line 38 was replaced by lines 40-41 |
- Ten pin connector on cryostat top plate :Heater and carbon resistor for clearing VTI needle valve blockages. |
+ Five pin connector on services neck with motor drive: |
+ * Auto-needle valve control for the VTI. (not mounted). |
Line 40 was replaced by lines 43-44 |
- Five pin connector on services neck with motor drive :Auto-needle valve control for the VTI. |
+ Original Risų Cabling: |
+ [MA09WiringManual/OriginalRisoeCables.gif] |
Line 45 was replaced by line 49 |
- Please see circuit diagram. |
+ [MA09WiringManual/InternalWiring.gif] |
Removed lines 47-51 |
- [MA09WiringManual/AllenBradleyPlug.gif] |
- [MA09WiringManual/SwitchHeaterPlug.gif] |
- [MA09WiringManual/VTIPlug.gif] |
- [MA09WiringManual/NeedleValvePlug.gif] |
- [MA09WiringManual/OriginalRisoeCables.gif] |