Lines 4-7 were replaced by lines 4-6 |
- Stephan Fischer, Walter Latscha (technicians)\\ |
- [Marek Bartkowiak] (physicist)\\ |
- [Markus Zolliker] (physicist, software, general aspects)\\ |
- Ben van den Brandt (group leader "Sample Environment and Polarized Targets") |
+ [Marek Bartkowiak] (group leader)\\ |
+ [Markus Zolliker] (general aspects, controls)\\ |
+ Stephan Fischer, Paul Schurter, Silvan Stamm (technicians)\\ |
Line 9 was replaced by line 8 |
- [Sample Environment News|http://lns00/ldmwiki/Wiki.jsp?page=SampleEnvironmentNews] (internal) |
+ [Cryogenic safety at SINQ|http://lns00/ldmwiki/Wiki.jsp?page=CryogenicSafetyAtSINQ] (internal) |
Line 15 was replaced by line 14 |
- * [Dilution and He3 cryostats|DilutionCryostats] |
+ * [Dilution cryostats|DilutionCryostats] |
At line 18 added 1 line. |
+ * [Electric Field|Efield] |
Line 50 was replaced by line 50 |
- at the ILL (now available for AS Scientific). |
+ at the ILL (now available from AS Scientific). |
Lines 56-57 were replaced by lines 56-58 |
- Supraconducting magnets are used to achieve magnetics fields up to 15 Tesla. The old 4 Tesla Magnet manufactured by Thor is limited in the temperature range, but has less stray fields and is therefore preferred on instruments with a magnetic environment. The |
- [Oxford Instruments|http://www.oxford-instruments.com/] Cryomagnets may be used with sample temperatures from 300 K down to 0.1 K when combined with the dilution stick. |
+ Supraconducting magnets are used to achieve magnetics fields up to 15 Tesla. The |
+ [Oxford Instruments|http://www.oxford-instruments.com/] Cryomagnets may be used with |
+ sample temperatures from 300 K down to 0.1 K when combined with the dilution stick. |
At line 63 added 3 lines. |
+ !Electric Fields |
+ A versatile high voltage sample stick that fits into all of our cryomagnets and standard cryostats is available. The stick allows for voltages up to 5 kV and can be easily adapted for different scattering geometries. For details see [electric Field|Efield]. |
+ |
Line 65 was replaced by line 69 |
- The main temperature controller is the LakeShore Model 340. Under [Additional Equipment] |
+ The main temperature controllers used are the LakeShore Models 340, 336 and 370. Under [Additional Equipment] |
Removed lines 73-74 |
- * [serial connections] |
- * [LS340 devices codes|Lsc340Codes] |