Line 16 was replaced by line 16 |
- * __HRPT, ZEBRA, TASP, EIGER, CAMEA, FOCUS, SANS-I, AMOR__ |
+ * __HRPT, ZEBRA, TASP, EIGER, CAMEA, FOCUS, SANS-I, AMOR, BOA__ |
Line 24 was replaced by line 24 |
- By default a setup 'frappy' is loaded providing the following commands: |
+ By default a setup 'frappy' is loaded providing the following commands:\\ |
Removed line 26 |
- |
Lines 28-33 were replaced by lines 27-32 |
- frappy_main('<main cfg>') # change main SE configuration (e.g. cryostat) |
- frappy_stick('<stick cfg>') # change sample-stick configuration |
- frappy_stick('') # remove stick |
- frappy_main('') # remove main SE apparatus |
- frappy_main() # show the current SE configuration |
- frappy_addons(...) # similar to above, for additional equipment not covered by main/stick |
+ frappy('<main cfg>') # change main SE configuration (e.g. cryostat) |
+ frappy('<main cfg>', '<stick cfg>') # change main and sample-stick configuration |
+ frappy(stick='<stick cfg>') # change stick only |
+ frappy('') # remove main SE apparatus including stick |
+ frappy() # show the current SE configuration |
+ frappy(addons=...) # similar to above, for additional equipment not covered by main/stick |
At line 36 added 8 lines. |
+ ''note: use {{AddSetup('frappy')}} if the setup is not yet loaded'' |
+ |
+ |
+ !! Test integration of SE into NICOS |
+ |
+ For testing there are 2 simulated main devices 'cryosim' and 'magsim' available. Please check with them if |
+ temperatures and magnetic field values are saved in your datafile, and other things like temperature or |
+ magnetic field scans. |
At line 72 added 32 lines. |
+ |
+ ! How to Restart a Frappy server |
+ |
+ If a sample environment device is not working properly, for example due to communication |
+ problems, it might be helpful to stop and restart the frappy server: |
+ {{{ |
+ frappy('') # stop main and stick frappy servers |
+ frappy('<main cfg>', '<stick cfg>') # start main and stick frappy servers |
+ }}} |
+ |
+ If the problem is related to a device on the stick or addons, you will need the commands frappy_stick or frappy_addons. |
+ |
+ ! How do I configure to use the sample stick rotation instead of the sample table for omega? |
+ |
+ With vertical field cryomagnets, typically the stick rotation should be used instead of the |
+ standard sample table for omega. In this case (currently configured on ZEBRA and TASP), |
+ the frappy_main setups should contain a device __se_om__ for the stick rotation. This is |
+ automatically assigned to the device used for omega. |
+ |
+ ||Instrument || name of omega || name of sample table |
+ |ZEBRA | om | om_raw |
+ |TASP | a3 | a3_st |
+ |CAMEA | a3 | som |
+ |
+ On horizontal field magnets, the stick rotation is called __om_stick__, and is |
+ not automatically assigned to omega. In both cases, an alias __dom__ is assigned to |
+ either __se_om__ or __se_stickrot__, whatever is present. |
+ |
+ To change this behaviour, it is possible to assign another device to the alias, e.g. |
+ |
+ {{om.alias = se_stickrot}} |
+ |