Lines 1-40 were replaced by lines 1-75 |
- !Common Parameters and Subcommands for all EASE Objects |
- {{{ |
- Command Syntax Description Defined by[2] |
- }}} |
- Standard commands defined for all objects based on pardef: |
- {{{ |
- <obj> list c make a list of most important parameters (all parameters defined with a call to ParTail and not ParList, or with a call to ParList(NULL) |
- <obj> list all c make a full list of all parameters |
- <obj> list <group> c make a list of only a group of parameters (all parameters defined with a call to ParList("<group>") ) |
- <obj> log <par> c switch the logger on for parameter <par> (on for parameters defined without an explicit call to ParSwitch(NULL) ) |
- <obj> log <par> <sugar> c switch the logger on for parameter <par>, giving a sugar name (see [SicsSugar]) |
- <obj> unlog <par> c switch the logger off for parameter <par> |
- <obj> sugar c return a list of sugar parameters |
- <obj> save <par> c switch on status file saving for parameter <par> (on for changeable parameters, or explicitley when defined with a call to ParSave |
- <obj> unsave <par> c switch off status file saving for parameter <par> |
- <obj> interest c switch interest callback on (every change will be notified to the executive client) |
- <obj> uninterest c switch interest callback off |
- }}} |
- Parameters defined in ParStdDef |
- {{{ |
- <obj> verbose w verbosity. 0 is quiet, 1 is standard, 2 is verbose (logging all serial communication) |
- <obj> driver r driver name |
- <obj> creationCmd r command to create this object |
- }}} |
- Parameter defined by EaseBasePar |
- {{{ |
- <obj> restart c reconnect serial connection |
- }}} |
- Parameter defined by EaseSendPar |
- {{{ |
- <obj> send <command> c send a serial command. Warning: the resonse is delayed and can therefore not be used in scripts. |
- }}} |
- Parameters defined by EaseDrivPar |
- {{{ |
- <obj> upperLimit w upper limit of target value |
- <obj> lowerLimit w lower limit of target value |
- <obj> tolerance w tolerance |
- <obj> maxwait w maximal time to wait for target value (sec) or 0 for infinite wait |
- <obj> settle w time to wait after target value is within tolerance |
- <obj> targetValue r target value |
+ !Common Parameters and Subcommands for EASE Objects |
+ |
+ {{(c)}}: command\\ |
+ {{(r)}}: read-only parameters\\ |
+ {{(w)}}: writeable parameter. The value has to be added to the command. |
+ |
+ {{{ |
+ Command Syntax Description |
+ }}} |
+ ''Standard commands defined for all objects based on pardef'' |
+ {{{ |
+ <obj> list (c) make a list of most important parameters. listed |
+ are all parameters defined with a call to ParTail |
+ and not ParList, or with a call to ParList(NULL) |
+ |
+ <obj> list all (c) make a full list of all parameters |
+ |
+ <obj> list <group> (c) make a list of only a group of parameters. listed |
+ are all parameters defined with a call to |
+ ParList("<group>") |
+ |
+ <obj> log <par> (c) switch the logger on for parameter <par>. logging |
+ is on by default, off when defined without an |
+ explicit call to ParSwitch(NULL) |
+ |
+ <obj> log <par> <sugar> (c) switch the logger on for parameter <par>, giving |
+ a sugar name (see [SicsSugar]) |
+ |
+ <obj> unlog <par> (c) switch the logger off for parameter <par> |
+ |
+ <obj> sugar (c) return a list of sugar parameters |
+ |
+ <obj> save <par> (c) switch on status file saving for parameter <par> |
+ is on by default for changeable parameters, or |
+ when explicitley defined with a call to ParSave |
+ |
+ <obj> unsave <par> (c) switch off status file saving for parameter <par> |
+ |
+ <obj> interest (c) switch interest callback on. every change will |
+ be notified to the calling client |
+ |
+ <obj> uninterest (c) switch interest callback off |
+ }}} |
+ ''Parameters defined in ParStdDef'' |
+ {{{ |
+ <obj> verbose (w) verbosity. 0 is quiet, 1 is standard |
+ 2 is verbose (logging all serial communication) |
+ |
+ <obj> driver (r) driver name |
+ |
+ <obj> creationCmd (r) command to create this object |
+ }}} |
+ ''Parameter defined by EaseBasePar'' |
+ {{{ |
+ <obj> restart (c) reconnect serial connection |
+ }}} |
+ ''Parameter defined by EaseSendPar'' |
+ {{{ |
+ <obj> send <command> (c) send a serial command. Warning: the response is |
+ delayed and can therefore not be used in scripts. |
+ }}} |
+ ''Parameters defined by EaseDrivPar'' |
+ {{{ |
+ <obj> upperLimit (w) upper limit of target value |
+ |
+ <obj> lowerLimit (w) lower limit of target value |
+ |
+ <obj> tolerance (w) tolerance |
+ |
+ <obj> maxwait (w) maximal time to wait for target value (sec) |
+ or 0 for infinite wait |
+ |
+ <obj> settle (w) time to wait after target value is within tolerance |
+ |
+ <obj> targetValue (r) target value |
Line 42 was replaced by line 77 |
- Parameter defined by EaseMsgPar |
+ ''Parameter defined by EaseMsgPar'' |
Line 44 was replaced by line 79 |
- <obj> status r connection status of the device (empty when normal) |
+ <obj> status (r) connection status of the device (empty when normal) |
Removed line 46 |
- c: command, r: read-only parameters, w: writeable parameter |